Building Regulations Part H Disposal hierarchy and SuDS best practice standards prioritise the use of infiltration for surface water discharge. Infiltration helps reduce flood risk, improve water quality, and mimics the natural water cycle. When designing and implementing infiltration systems, consideration must be given to local ground conditions, proximity to buildings and infrastructure, to ensure long-term effectiveness and structural safety. In this article we outline the key considerations for using infiltration, particularly soakaways, in civil engineering and drainage design.
Local Geology / ground conditions
The suitability of the local geology for supporting infiltration is determined by BRE 365 tests, with a minimum infiltration rate required of 1 × 10⁻⁶ m/s. This is based on CIRIA SuDS Guidance C753 and design standards for most Lead Local Flood Authorities (LLFAs). This ensures the infiltration structure can empty to half its capacity is less than 24 hours, and provide further capacity for consecutive storm events. For adoptable designs, higher rates may be required.
However, even when the percolation rate is sufficient, infiltration features should be located at a safe distance from buildings. In accordance with Building Regulations Part H, soakaways must be at least 5 metres away from buildings.
When Do Soakaways Need to Be More Than 5 Metres Away from Buildings and Public Roads?
Building Regulations Part H states that soakaways should not be placed in areas of unstable land (at risk of landslide or slope instability as stated on Planning Policy Guidance 14: Development on Unstable Land – Annex 1). Although a detailed ground investigation is required to determine if the land is unstable, instability is often attributed to sites where chalk is present as there is a risk of dissolution.
Can an Infiltration Device Be Located Less Than 5 Metres from Buildings and Public Roads If It Is Not a Soakaway?
According to CIRIA’s ‘Using SuDS Close to Buildings’ guidance, the 5-metre rule in the Building Regulations was originally devised as a general rule of thumb. Many SuDS methods differ from traditional soakaways in structure and function.
Conclusion
Infiltration remains the most sustainable and preferred method for surface water management. Civil Engineers and developers should understand the implications of SuDS solutions and how to align infiltration strategies with current regulations and best practices in order to deliver robust and resilient drainage designs.
Civilistix Services:
News & Views

November 12, 2026
Topographical surveys help identify overland flow routes and low points where water may collect. Accurate survey information supports informed drainage design, flood risk assessment and site layout decisions from the outset.

November 6, 2026
Manhole backdrops can offer excavation savings and design flexibility, but introduce hydraulic and maintenance challenges. Their use requires careful consideration of site constraints, adoption requirements and long-term drainage system performance.

October 29, 2026
Drainage easements can influence building positions, drainage strategies and development costs. Identifying these constraints early helps project teams coordinate site layouts, maintain sewer access and avoid unnecessary redesign or diversions.