Linkedin

Newsletter Q1, 2026

March 11, 2026

2026 – Get Set …. GO!

At the start of 2026 we came together as a team to reflect and plan for the year ahead. Not exactly New Year’s resolutions, more like a clear, intentional path for how we want to operate and grow as a business.

As part of our discussions we decided that this year we were going to focus on OPTIMISATION.

Our goal is to optimise our time, our systems and our services. For our clients, this means a  renewed commitment to right-first-time solutions.

  • Thought out designs.
  • Clear communication.
  • Efficient delivery.

For us as a civil engineering consultancy specialising in drainage and highways design, optimisation is about refining technical workflows, strengthening internal processes, and continually improving how we collaborate with all parties involved in a project, so that all our projects move smoothly from concept through to delivery.

And while we take our work seriously, we are certainly not all work and no play.

It’s our birthday month and that deserves a celebration!

We are so grateful to be celebrating another year and would like to say THANK YOU to all our wonderful clients for your support!

Here’s to a great 2026 together!

A sewer diversion is required when a proposed development or construction project intersects with, or is in close proximity to, an existing public sewer and it is deemed unsafe to build over it. In such cases, it becomes necessary to alter the sewer’s route to accommodate the development while ensuring the sewer’s functionality is maintained.

The process is governed by Section 185 of the Water Industry Act 1991, which permits developers to request the alteration or removal of public water or wastewater assets.

Most relevant considerations include the following:

  • Size of the sewer
    For small pipes, typically up to 300mm in diameter, the sewer undertaker may permit the works to be undertaken by the developer, ensuring their easement requirements are met (typically between 3 – 5 m). In contrast, the most challenging scenario arises when the sewer is classified as a ‘strategic sewer.’ In such cases, the sewer undertaker usually assumes responsibility for the diversion works to ensure compliance with technical and safety standards. This will have a significant impact on project timelines, as undertakers may take up to 18 months to finalise the works.
  • Access manholes
    If access manholes are located within the proposed development site, they may need to be relocated to ensure the sewer undertaker can maintain access for maintenance purposes. Manholes can typically be repositioned to external areas within the site boundary, which are easily accessible or within the public highway. If it can be demonstrated that the sewer remains accessible upstream and downstream of the site post-development, the installation of new manholes may be omitted.
  • Available land for the diversion:
    As a general rule, the diverted sewer must maintain a minimum distance of 3 meters from any buildings. This requirement may pose challenges on some sites, particularly when space is constrained. In such cases, a Build Over Agreement with the sewer undertaker may be necessary to ensure the proposed development does not compromise the sewer or ongoing maintenance activity of it.

Additionally, the design of external areas must be coordinated with the diversion works, as the sewer undertaker generally prohibits the placement of features such as permeable paving or trees directly over their pipes.

If the diversion includes works on 3rd party land, the sewer undertaker may exercise their powers (under Section 98 of the Water Industry Act 1991), to construct it regardless of third-party consent. It should be noted however exercising S98 powers will have a significant impact on costs and project timelines due to legal implications.

Hydraulic design

Once the above items have been clarified, a detailed hydraulic design needs to be submitted for the approval of the sewer undertaker. The design package will typically consist of the relevant plan and section drawings as well as the calculation package, to ensure the diversion works will not have a detrimental effect on the capacity of the sewer. The sewerage undertaker will typically expect the capacity of all proposed diverted sewers to be of the same or greater capacity than the existing sewer portion the diversion replaces. If the proposed diverted sewer portion is of a greater length than the existing sewer portion it replaces, to maintain capacity the proposed diverted sewer portion will need to be increased in diameter accordingly, due to the flatter overall gradient which will materialise. This needs to be carefully considered to protect downstream capacity, ensure accurate forecasting of costs and to ensure resultant technical hurdles (such as larger pipes leading to reduced cover) can be accommodated.

At Civilistix, we have extensive expertise in preparing comprehensive design packages for Section 185 submissions. We specialize in liaising with sewer undertakers to secure approvals for designs that ensure the viability and success of your projects.

  • Preparation of a Utility Statement / Appraisal Report

Civilistix Consulting Engineers was commissioned to prepare a Utility Statement to support a planning application for the proposed redevelopment of the site consisting of commercial space (Class E), gallery use (Class F1) and nine residential units (C3).

The purpose of our Utility Statement was to review the presence of all underground utilities operated by local statutory undertakers within the vicinity of the site, and to determine the effect the proposed development may have on these utilities.

This included:

  • Obtaining underground asset plans from all local utility providers to confirm the extent of their underground utility assets within the vicinity of the development.
  • Preparing a combined utility plan showing the proximity of the development to all mainline services to assess connection feasibility and whether diversion of any existing services would be necessary.
  • Understanding any future utility considerations necessary to support the development proposals.
  • Determining if existing utilities could satisfactorily support development proposals or would need to be upgraded.

In terms of Drainage Design, it is important to understand the intricate web of agreements governing infrastructure development. From pre-planning to post-planning stages, various applications and agreements with sewerage undertakers must be considered to ensure compliance and efficiency in drainage infrastructure.

Here, we explore the main steps and applications involved at each stage:

Pre-Planning Stage:

  1. Acquiring Sewerage Undertakers’ Asset Mapping: Accessing asset mapping from sewerage undertakers provides valuable insights into existing drainage infrastructure within and around the development site. Understanding the location and capacity of sewers, pumping stations, and other assets helps developers assess feasibility and plan drainage solutions that integrate seamlessly with the existing network. 
  1. Pre-Planning Enquiry Application: Developers initiate discussions with sewerage undertakers through pre-planning enquiries. This allows developers to seek guidance and information on drainage infrastructure capacity, constraints, and requirements within a proposed development area. It helps identify potential challenges early in the planning process and informs subsequent design decisions.

Post-Planning Stage:

  1. Section 104 Agreements: Section 104 agreement of the Water Industry Act 1991 governs the process by which newly constructed sewerage infrastructure is adopted and maintained by sewerage undertakers. Developers must adhere to strict design and construction standards outlined in the agreement to ensure that the infrastructure meets the requirements for adoption. Sewerage Sector Guidance Appendix C – serves as the primary guidance for developers when planning, designing, and constructing foul and surface water drainage systems intended for adoption under Section 104 agreements.
  2. Section 106 Agreements: Section 106 agreement of the Water Industry Act (1991) grants developers the right to discharge foul and surface water into public sewers owned by local water companies, with the obligation to inform the sewerage undertakes in advance which will approve or defer based on capacity or connection standards. There are two types of Section 106 connections: direct, involving physical connections to public sewers, and indirect, using existing private drains. Even though indirect connections do not involve physical alterations to public sewers, an agreement is still necessary to inform the water company about any change in the type or increased in flows from the development.
  3. Sewer Diversion Agreements: When existing sewers need to be diverted to accommodate development or infrastructure projects, sewer diversion agreements are made between developers and sewerage undertakers. These agreements outline responsibilities for diversion works and ensure minimal disruption to existing drainage infrastructure.

Navigating the complexities of drainage planning in the UK requires close collaboration with sewerage undertakers at every stage of the development process. By engaging early and proactively addressing drainage considerations, developers can ensure compliant, resilient, and sustainable drainage solutions. At Civilistix, we specialize in managing these applications with sewerage undertakers. We simplify your entire drainage design process! Top of FormAt Civilistix, we specialize in liaising with sewerage undertakers. Allow us to streamline your entire drainage design journey for you

Why do we need a CCTV drainage survey?

A CCTV survey confirms the condition and layout of existing sewers and connections.

Without this survey, designs may rely on assumptions, which can lead to unexpected costs during construction. In many cases, it has been discovered that existing pipes serving more than one property (and therefore adopted) run beneath proposed foundations or require diversion. In such situations works must be agreed with the relevant sewerage undertaker and can add significate time and cost to a project if not identified early.

 

Civilistix, a Civil Engineering Design Consultancy promoting constructive conversations in Civil Engineering and your….

Civilistix Services Offered

Planning services: Planning Services Cambridge | Civilistix

Highway services: Highway Engineering Cambridge | Civilistix

Drainage engineering: Drainage Engineering Cambridge | Civilistix

Surveying services: Surveying Services | Civilistix

We would love to help you with your next project! Contact us | Civilistix

 

News & Views

Latest Updates

Manhole Backdrops: The Pros and Cons

November 6, 2026

Manhole Backdrops: The Pros and Cons

Manhole backdrops can offer excavation savings and design flexibility, but introduce hydraulic and maintenance challenges. Their use requires careful consideration of site constraints, adoption requirements and long-term drainage system performance.

Why Drainage Easements Matter to Site Layout and Detailed Design

October 29, 2026

Why Drainage Easements Matter to Site Layout and Detailed Design

Drainage easements can influence building positions, drainage strategies and development costs. Identifying these constraints early helps project teams coordinate site layouts, maintain sewer access and avoid unnecessary redesign or diversions.

Designing Safe Pedestrian Routes Across Vehicle Accesses

October 23, 2026

Designing Safe Pedestrian Routes Across Vehicle Accesses

Safe pedestrian routes require careful coordination where they cross vehicle accesses. We explore how layout, visibility, vehicle speeds, accessibility and drainage help create safe pedestrian crossings.