June 5, 2025
Summer Time!
Summer is here! The days are longer, the sun in shining and there is a feeling of happiness in the air. We have enjoyed a wonderful Spring – filled with sunshine to boost our vitamin D levels.
With summer – comes holidays! Socials are full of smiling faces and pictures of well-deserved breaks. So we asked our team what their “perfect holiday” looks like:
Here’s what summer fun looks like for us:
We have also seen an increase in our work load which we are truly thankful for. Returning clients and recommendations remind us that we are on the right track.
Our skilled engineers, have been sharing their knowledge through truly insightful articles and case studies, a selection of which we are happy to share with you now.

What is a Road Safety Audit?
A Road Safety Audit (RSA) is an independent assessment of the potential road safety issues associated with new or modified highway schemes. It ensures that all designs meet the safety standards outlined in the Design Manual for Roads and Bridges (DMRB) and all other relevant guidances, minimizing risks to road users and ensuring long-term project success.
For projects carried out under S278 Agreements, RSAs are essential in securing approval from the Local Highway Authorities (LHA). These audits are conducted in distinct stages, each aligned with the project lifecycle as defined in the DMRB GG 119:
Stage 1: Preliminary Design Audit: This stage occurs after the preliminary design is completed but before detailed design begins. The focus is on identifying high-level safety risks associated with the scheme’s layout. For example, poorly designed junctions may create confusion for drivers, while incorrectly placed pedestrian crossings could increase the risk of accidents. Additionally, lane widths or road alignments that do not consider future traffic volumes or vehicle types can compromise safety.
Stage 2: Detailed Design Audit: This stage takes place once the detailed design is complete. At this stage, the audit examines the scheme’s specific features in-depth to identify risks arising from the design details. Examples include inadequate drainage that can lead to hazardous surface water accumulation, gradients that are too steep for safe braking, or insufficient sight distances for drivers. Roadside features, such as poorly placed signs or barriers, can also present hazards if they are not visible or do not meet safety standards.
Stage 3: Post-Construction (Pre-Opening) Audit: Conducted after construction but before the scheme opens to road users, this stage assesses how the as-built infrastructure matches the intended design and whether it introduces any unexpected hazards. For instance, improperly installed safety barriers may fail to protect users in an accident, and worn or incorrectly applied road markings can confuse drivers. Lighting conditions can also reveal potential visibility issues, particularly in areas with sharp bends or pedestrian crossings.
Stage 4: Monitoring Audit: This stage takes place 12 months after the road or highway scheme opens, evaluating its performance under real-world conditions. Emerging issues might include unforeseen accident hotspots or inappropriate driver behaviour, such as speeding in areas where traffic-calming measures were expected to slow vehicles. In some cases, poor landscaping or vegetation growth may obstruct sightlines, while wear and tear on surfaces or markings may compromise safety over time.
It is important to note that RSAs may be conducted either by private, independent companies or directly by the Local Highway Authority’s in-house team, depending on the LHA’s policies. This highlights the importance of understanding each LHA’s specific policies. Engaging with the LHA early in the project helps clarify their preferred process for RSAs, ensuring compliance and avoiding unnecessary delays.
At Civilistix, we specialize in navigating the complexities of S278 Agreements, including the integration of RSAs at all stages of highway design. If you’re planning a highway scheme or need support with road safety audits, don´t hesitate to get in touch with our team.

Civilistix Consulting Engineers were appointed to prepare a detailed drainage, external hardstanding & adoptable highway vehicle crossover engineering package to help deliver 3No. 4-storey residential blocks providing 63No. residential units in total, along with courtyard and associated external hardstanding areas.
The existing brownfield site consisted of three industrial units with associated carparking and access and a total area of approximately 0.401 hectares.
Our fully coordinated drainage solution utilised a gravity drained foul water network for all 3No. 4-storey residential blocks. The proposed storm water network also utilised a gravity drained pipe network, where runoff was attenuated via a lined attenuation tank before entering the public sewer infrastructure.
Our fully coordinated external works package included level design, kerb layout design and full depth construction details for proposed hardstanding. We were tasked to provide finished ground levels and set proposed Finished Floor Levels (FFL’s) for the proposed developments within the private boundary extents.
Challenges overcome:
Find the full case study on our website: Project Mayday Rd

Recently we loaded our +- 800 projects onto Google maps so we could access information on projects in common flood zones and common local authority sectors. It was impressive to see how many projects we have undertaken to date, and also our coverage within the UK.

Half drain time is a key parameter in the design of Sustainable Drainage Systems (SuDS) and drainage attenuation features. It refers to the time required for an attenuation system—such as a detention basin, pond, or underground storage tank—to drain 50% of its stored water volume following a storm event. This metric is essential in assessing the system’s future ability to manage runoff after a rainfall event has occurred, whether it’s through infiltration into the ground or discharge to waterbodies or sewers.
A longer half drain down time signals reduced capacity to manage additional future rainfall, leading to potential flooding or overflow.
Typical Requirements from the SuDS Manual and LLFAs
Factors Affecting Half Drain Time
Several factors influence the half drain time of a drainage attenuation system:
Conclusion
Half drain time is a critical design parameter in drainage attenuation systems, influencing how effectively water is managed, either through infiltration into the ground or discharge to sewers and watercourses. Properly achieving the required half-drain time ensures flood risk is minimized and that systems can cope with future rainfall events. Following the guidelines outlined in the SuDS Manual and meeting the expectations of LLFAs, is vital for designing efficient drainage systems. Regular maintenance, accurate hydraulic modelling, and careful planning are key to ensuring optimal performance and stormwater management.

Building Regulations Part H Disposal hierarchy and SuDS best practice standards prioritise the use of infiltration for surface water discharge. Infiltration helps reduce flood risk, improve water quality, and mimics the natural water cycle. When designing and implementing infiltration systems, consideration must be given to local ground conditions, proximity to buildings and infrastructure, to ensure long-term effectiveness and structural safety. In this article we outline the key considerations for using infiltration, particularly soakaways, in civil engineering and drainage design.
Local Geology / ground conditions
The suitability of the local geology for supporting infiltration is determined by BRE 365 tests, with a minimum infiltration rate required of 1 × 10⁻⁶ m/s. This is based on CIRIA SuDS Guidance C753 and design standards for most Lead Local Flood Authorities (LLFAs). This ensures the infiltration structure can empty to half its capacity is less than 24 hours and provide further capacity for consecutive storm events. For adoptable designs, higher rates may be required.
However, even when the percolation rate is sufficient, infiltration features should be located at a safe distance from buildings. In accordance with Building Regulations Part H, soakaways must be at least 5 metres away from buildings.
When Do Soakaways Need to Be More Than 5 Metres Away from Buildings and Public Roads?
Building Regulations Part H states that soakaways should not be placed in areas of unstable land (at risk of landslide or slope instability as stated on Planning Policy Guidance 14: Development on Unstable Land – Annex 1. Although a detailed ground investigation is required to determine if the land is unstable, instability is often attributed to sites where chalk is present as there is a risk of dissolution.
Can an Infiltration Device Be Located Less Than 5 Metres from Buildings and Public Roads If It Is Not a Soakaway?
According to CIRIA’s ‘Using SuDS Close to Buildings’ guidance, the 5-metre rule in the Building Regulations was originally devised as a general rule of thumb. Many SuDS methods differ from traditional soakaways in structure and function.
Conclusion
Infiltration remains the most sustainable and preferred method for surface water management. Civil Engineers and developers should understand the implications of SuDS solutions and how to align infiltration strategies with current regulations and best practices in order to deliver robust and resilient drainage designs.

5 Common mistakes made in Surface Water Network modelling:
Surface water network modelling is beneficial for various applications, including flood forecasting and management, water supply planning, water quality analysis, and environmental impact assessments. It is important to make sure that we as engineers supply the correct information so that decision makers on a project can make informed choices.
Civilistix Services Offered
Planning services: Planning Services Cambridge | Civilistix
Highway services: Highway Engineering Cambridge | Civilistix
Drainage engineering: Drainage Engineering Cambridge | Civilistix
Surveying services: Surveying Services | Civilistix
News & Views

November 12, 2026
Topographical surveys help identify overland flow routes and low points where water may collect. Accurate survey information supports informed drainage design, flood risk assessment and site layout decisions from the outset.

November 6, 2026
Manhole backdrops can offer excavation savings and design flexibility, but introduce hydraulic and maintenance challenges. Their use requires careful consideration of site constraints, adoption requirements and long-term drainage system performance.

October 29, 2026
Drainage easements can influence building positions, drainage strategies and development costs. Identifying these constraints early helps project teams coordinate site layouts, maintain sewer access and avoid unnecessary redesign or diversions.