Linkedin

Newsletter Q2, 2025

June 5, 2025

Summer Time!   

Summer is here!  The days are longer, the sun in shining and there is a feeling of happiness in the air.  We have enjoyed a wonderful Spring – filled with sunshine to boost our vitamin D levels.

With summer – comes holidays!  Socials are full of smiling faces and pictures of well-deserved breaks.  So we asked our team what their “perfect holiday” looks like:

Here’s what summer fun looks like for us:

  • Dan – Cardio & Catchup: a tough cycle ride and then a catchup with family and friends over a BBQ.
  • Fran – Romantic reconnect: a short trip away with his wife.  Good food, good company and time to unwind.
  • Yaré – Perfect Surf Spot: sun, sea and a good book
  • Kevin – Fishing! Beach, deep sea and off a kayak
  • Karen – Road Trip: discovering travel gems with family.

We have also seen an increase in our work load which we are truly thankful for.  Returning clients and recommendations remind us that we are on the right track.

Our skilled engineers, have been sharing their knowledge through truly insightful articles and case studies, a selection of which we are happy to share with you now.

What is a Road Safety Audit?
A Road Safety Audit (RSA) is an independent assessment of the potential road safety issues associated with new or modified highway schemes. It ensures that all designs meet the safety standards outlined in the Design Manual for Roads and Bridges (DMRB) and all other relevant guidances, minimizing risks to road users and ensuring long-term project success.

For projects carried out under S278 Agreements, RSAs are essential in securing approval from the Local Highway Authorities (LHA). These audits are conducted in distinct stages, each aligned with the project lifecycle as defined in the DMRB GG 119:

Stage 1: Preliminary Design Audit: This stage occurs after the preliminary design is completed but before detailed design begins. The focus is on identifying high-level safety risks associated with the scheme’s layout. For example, poorly designed junctions may create confusion for drivers, while incorrectly placed pedestrian crossings could increase the risk of accidents. Additionally, lane widths or road alignments that do not consider future traffic volumes or vehicle types can compromise safety.

Stage 2: Detailed Design Audit: This stage takes place once the detailed design is complete. At this stage, the audit examines the scheme’s specific features in-depth to identify risks arising from the design details. Examples include inadequate drainage that can lead to hazardous surface water accumulation, gradients that are too steep for safe braking, or insufficient sight distances for drivers. Roadside features, such as poorly placed signs or barriers, can also present hazards if they are not visible or do not meet safety standards.

Stage 3: Post-Construction (Pre-Opening) Audit: Conducted after construction but before the scheme opens to road users, this stage assesses how the as-built infrastructure matches the intended design and whether it introduces any unexpected hazards. For instance, improperly installed safety barriers may fail to protect users in an accident, and worn or incorrectly applied road markings can confuse drivers. Lighting conditions can also reveal potential visibility issues, particularly in areas with sharp bends or pedestrian crossings.

Stage 4: Monitoring Audit: This stage takes place 12 months after the road or highway scheme opens, evaluating its performance under real-world conditions. Emerging issues might include unforeseen accident hotspots or inappropriate driver behaviour, such as speeding in areas where traffic-calming measures were expected to slow vehicles. In some cases, poor landscaping or vegetation growth may obstruct sightlines, while wear and tear on surfaces or markings may compromise safety over time.

It is important to note that RSAs may be conducted either by private, independent companies or directly by the Local Highway Authority’s in-house team, depending on the LHA’s policies. This highlights the importance of understanding each LHA’s specific policies. Engaging with the LHA early in the project helps clarify their preferred process for RSAs, ensuring compliance and avoiding unnecessary delays.

At Civilistix, we specialize in navigating the complexities of S278 Agreements, including the integration of RSAs at all stages of highway design. If you’re planning a highway scheme or need support with road safety audits, don´t hesitate to get in touch with our team.

Civilistix Consulting Engineers were appointed to prepare a detailed drainage, external hardstanding & adoptable highway vehicle crossover engineering package to help deliver 3No. 4-storey residential blocks providing 63No. residential units in total, along with courtyard and associated external hardstanding areas.

The existing brownfield site consisted of three industrial units with associated carparking and access and a total area of approximately 0.401 hectares.

Our fully coordinated drainage solution utilised a gravity drained foul water network for all 3No. 4-storey residential blocks. The proposed storm water network also utilised a gravity drained pipe network, where runoff was attenuated via a lined attenuation tank before entering the public sewer infrastructure.

Our fully coordinated external works package included level design, kerb layout design and full depth construction details for proposed hardstanding. We were tasked to provide finished ground levels and set proposed Finished Floor Levels (FFL’s) for the proposed developments within the private boundary extents.

Challenges overcome:

  • Coordinated our proposals to suit design team proposals and flag up any major comments on design team proposals and relay to design team.
  • Setting appropriate FFLs for all buildings allowing for sufficient access and drainage infrastructure coordination.
  • Providing separate attenuation storage tank positions due to spatial, ecological, and proposed building constraints.

Find the full case study on our website:  Project Mayday Rd

 

Recently we loaded our +- 800 projects onto Google maps so we could access information on projects in common flood zones and common local authority sectors. It was impressive to see how many projects we have undertaken to date, and also our coverage within the UK.

 

Half drain time is a key parameter in the design of Sustainable Drainage Systems (SuDS) and drainage attenuation features. It refers to the time required for an attenuation system—such as a detention basin, pond, or underground storage tank—to drain 50% of its stored water volume following a storm event. This metric is essential in assessing the system’s future ability to manage runoff after a rainfall event has occurred, whether it’s through infiltration into the ground or discharge to waterbodies or sewers.

A longer half drain down time signals reduced capacity to manage additional future rainfall, leading to potential flooding or overflow.

Typical Requirements from the SuDS Manual and LLFAs

  • SuDS Manual (CIRIA C753): The CIRIA C753 manual recommends that drainage systems should aim for a half drain time of 24 hours for systems handling a 1 in 30-year return period event (typical storm conditions). However, when the system is designed for larger events, such as those beyond the 1 in 30-year event (e.g. a 1 in 100 year event), achieving a 24-hour half drain time can require significant storage, potentially making it impractical. In these cases, longer half-drain times may be acceptable, subject to agreement with the approving body.
  • Lead Local Flood Authorities (LLFAs): LLFAs, which manage local flood risk, often set specific requirements for drainage systems submitted for planning approval. A common requirement from LLFAs is that storage features and infiltration systems should achieve a half-drain time within 24 hours for storms up to and including the 1 in 30-year event. If achieving this is not possible, LLFAs expect the system to handle a 1 in 30-year storm event plus climate change, followed by a 1 in 10-year event.

Factors Affecting Half Drain Time

Several factors influence the half drain time of a drainage attenuation system:

  1. Permeability of the underlying soil: The infiltration rate of the soil is one of the most significant factors. Soils with high permeability (e.g. sandy soils) allow water to drain quickly, reducing half-drain time, while low permeability soils (e.g. clay) result in slower drainage, increasing the half-drain time.
  2. Outlet Control Structures: Flow control devices like orifices, weirs, and Hydro-Brake devices regulate water discharge rates. If discharge rates are set too low, the tank takes too long to drain, causing future flood risk.
  3. Storage volume and shape of the attenuation system: The volume and design (e.g., flat, deep, or wide) of attenuation features affect the time needed to drain, as this is directly related to the feature area in contact with the ground, when using infiltration.
  4. Rainfall intensity and volume: Higher rainfall intensity and volume directly affect the water that needs to be drained. More intense storms or prolonged rainfall events may fill the system more quickly, increasing the time needed for drainage.
  5. Surface water runoff coefficient: The runoff coefficient measures how much rainwater runs off a surface rather than infiltrating. Impermeable surfaces like roads, roofs, and parking lots have a higher runoff coefficient, meaning they contribute more runoff and require more time to drain.
  6. Maintenance and blockages: A poorly maintained system or one with blockages (e.g., debris or sediment buildup) can slow water flow, leading to longer half-drain times.

Conclusion

Half drain time is a critical design parameter in drainage attenuation systems, influencing how effectively water is managed, either through infiltration into the ground or discharge to sewers and watercourses. Properly achieving the required half-drain time ensures flood risk is minimized and that systems can cope with future rainfall events. Following the guidelines outlined in the SuDS Manual and meeting the expectations of LLFAs, is vital for designing efficient drainage systems. Regular maintenance, accurate hydraulic modelling, and careful planning are key to ensuring optimal performance and stormwater management.

Building Regulations Part H Disposal hierarchy and SuDS best practice standards prioritise the use of infiltration for surface water discharge. Infiltration helps reduce flood risk, improve water quality, and mimics the natural water cycle. When designing and implementing infiltration systems, consideration must be given to local ground conditions, proximity to buildings and infrastructure, to ensure long-term effectiveness and structural safety. In this article we outline the key considerations for using infiltration, particularly soakaways, in civil engineering and drainage design.

Local Geology / ground conditions

The suitability of the local geology for supporting infiltration is determined by BRE 365 tests, with a minimum infiltration rate required of 1 × 10⁻⁶ m/s. This is based on CIRIA SuDS Guidance C753 and design standards for most Lead Local Flood Authorities (LLFAs). This ensures the infiltration structure can empty to half its capacity is less than 24 hours and provide further capacity for consecutive storm events. For adoptable designs, higher rates may be required.

However, even when the percolation rate is sufficient, infiltration features should be located at a safe distance from buildings. In accordance with Building Regulations Part H, soakaways must be at least 5 metres away from buildings.

When Do Soakaways Need to Be More Than 5 Metres Away from Buildings and Public Roads?

Building Regulations Part H states that soakaways should not be placed in areas of unstable land (at risk of landslide or slope instability as stated on Planning Policy Guidance 14: Development on Unstable Land – Annex 1. Although a detailed ground investigation is required to determine if the land is unstable, instability is often attributed to sites where chalk is present as there is a risk of dissolution.

  • Most LLFAs require soakaways or any infiltration devices to be located at least 10 metres away from buildings and public roads where the local geology is chalk (Cambridgeshire County Council Surface Water Planning Guidance).
  • Where chalk is identified as low density, LLFAs may require this distance to be increased to 20 metres (The Sustainable Drainage Systems Design Guide for Essex).

Can an Infiltration Device Be Located Less Than 5 Metres from Buildings and Public Roads If It Is Not a Soakaway?

According to CIRIA’s ‘Using SuDS Close to Buildings’ guidance, the 5-metre rule in the Building Regulations was originally devised as a general rule of thumb. Many SuDS methods differ from traditional soakaways in structure and function.

  • The most typical blanket infiltration system is permeable paving, which can be located near buildings. This system captures rainwater at the surface level, typically over a large area, and allows infiltration to be spread across the entire sub-base at shallow depths, minimising concentrated flows. This contrasts with the point-source infiltration mechanism of a soakaway, which may produce lateral flows and pose a risk to foundations.
  • Where additional areas (such as runoff from building roofs) discharge into the permeable paving, point-source infiltration may occur. In such cases, the 5-metre separation distance should be applied.
  • Although the 5-metre rule was originally created as a rule of thumb, it remains a Building Regulations requirement and should be adhered to in all drainage designs, unless it has been agreed otherwise.

Conclusion

Infiltration remains the most sustainable and preferred method for surface water management. Civil Engineers and developers should understand the implications of SuDS solutions and how to align infiltration strategies with current regulations and best practices in order to deliver robust and resilient drainage designs.

5 Common mistakes made in Surface Water Network modelling:

  • Assigning incorrect operation head to a flow control: Whilst the flow rate of a flow control within a network model may be correctly limited to the greenfield rate or an otherwise agreed rate, the wrong operational head will mean during the critical event, more or less flow than intended will pass across the flow control.
  • Ensuring correct node / manhole sizing: If the node/manhole dimensions in a pipe network are not assigned correctly, it may lead to inaccurate storage volume calculations. This may lead to over or under provision of bespoke attenuation volumes within the attenuation structures.
  • Ensuring correct pipe gradients: Generally, and desirably, a self-cleansing velocity of 1.0 m/s or greater should be met within surface water pipe networks. If less than this, the pipe will become more prone to siltation buildup. If substantially greater, the result will be undesirable pipe depths and unnecessary costs to the client. 
  • Allowing for pipe sizes when making soffit-to-soffit connections: Where incoming/outgoing pipe sizes differ, allowance should be made to the connecting invert levels, to ensure a soffit-to-soffit connection is made irrespective of pipe size.
  • Not allowing for a potential surcharged outfall: A surcharged outflow can lead to internal building flooding and restricted outflow from the site, compromising performance of the drainage system. This risk should be accounted for during drainage modelling. Where private sewer levels are close to public sewer invert levels, measures should be undertaken to protect the private network from potential surcharging of the public sewer.

Surface water network modelling is beneficial for various applications, including flood forecasting and management, water supply planning, water quality analysis, and environmental impact assessments. It is important to make sure that we as engineers supply the correct information so that decision makers on a project can make informed choices.

 

Civilistix Services Offered

Planning services: Planning Services Cambridge | Civilistix

Highway services: Highway Engineering Cambridge | Civilistix

Drainage engineering: Drainage Engineering Cambridge | Civilistix

Surveying services: Surveying Services | Civilistix

News & Views

Latest Updates

How Topographical Surveys Inform Drainage Design

November 12, 2026

How Topographical Surveys Inform Drainage Design

Topographical surveys help identify overland flow routes and low points where water may collect. Accurate survey information supports informed drainage design, flood risk assessment and site layout decisions from the outset.

Manhole Backdrops: The Pros and Cons

November 6, 2026

Manhole Backdrops: The Pros and Cons

Manhole backdrops can offer excavation savings and design flexibility, but introduce hydraulic and maintenance challenges. Their use requires careful consideration of site constraints, adoption requirements and long-term drainage system performance.

Why Drainage Easements Matter to Site Layout and Detailed Design

October 29, 2026

Why Drainage Easements Matter to Site Layout and Detailed Design

Drainage easements can influence building positions, drainage strategies and development costs. Identifying these constraints early helps project teams coordinate site layouts, maintain sewer access and avoid unnecessary redesign or diversions.