Linkedin

Newsletter Q2, 2026

June 25, 2026

Halfway Through 2026!

It is hard to believe we are already approaching the halfway point of 2026! The first half of the year has been another busy and productive period for the Civilistix team, with projects progressing across a wide range of sectors from small residential extensions through to larger industrial developments. We really do enjoy the variety of our projects, and our team are proud of the designs we are delivering to support our clients in moving their projects forward.

Alongside a strong pipeline of ongoing and newly secured projects, we are also continuing to grow the team. We are currently looking to welcome a Senior Civil Engineer to Civilistix.

If you or someone you know may be interested, you can view the role on our website: Senior Civil Engineer .  We would be pleased to hear from anyone who feels they could be a good fit for our team.

attenuation_header

With the requirement of SuDS on almost every project, developers often approach the flood risk and drainage design with a question:

How big does the attenuation tank need to be?

Often, Developers will try to keep costs down by using a high-level estimate for site attenuation for planning submissions without doing a Detailed Drainage Design. Once on site however and the actual site constraints are evident (e.g. high voltage cables, steep topography), it is often assumed this previously estimated attenuation volume can be split between different locations and SuDS features (for example in the form of blueroof, permeable paving, geo-cellular storage tanks etc) without compromise.

This may work for minor planning applications and smaller projects, however due to some of the factors described below, this approach is not failsafe and can often lead to problems at the detailed design stage.

  • Steep sites and permeable paving. When working on developments with steep topography, the effectiveness of permeable paving might be reduced due to water flowing downstream too quickly and not using all the available space within the underlying pavement sub-base. To avoid this, it is necessary to create a flat sub-base formation level and/or use intermediate flow controls. However, when using intermediate flow controls, an additional delay is brought into the system resulting in the overall discharge capacity of the system slowing down, thus reducing the overall efficiency of the system as well as increasing blockage risk.
  • When the constraints are at ground level, an alternative attenuation of water could be achieved in the form of a blueroof. These are installed with their own flow control devices to maximise the use of storage spaces but similarly to the case above, will likely require a larger overall site attenuation volume due to the use of intermediate flow controls.
  • Half drain time capacity.When the attenuation tank is large and the imposed maximum flowrate is small, the drain down time of the structure is often greater than 24 hours. It is a standard planning requirement; the tank needs to half its volume within 24 hours of the critical attenuation level. This is often a challenge, and a general accepted compromise by approving authorities is to increase the tank size so it can attenuate a consecutive 10 return period storm after the critical rainfall event.

Preparing a Detailed Drainage Design from the onset will take into account these and other factors, using accurate hydraulic modelling to design a drainage strategy that works based on the independent constraints of the site.  This will save a developer time and money in the long run, by getting the drainage strategy right first time.

Civilistix Consulting Engineers were appointed to prepare the Detailed Drainage & External Hardstanding Design, together with the sewer agreements for Thames Water S185 approval. These works supported the  construction of 2no. tower blocks, 27 and 18 storeys respectively, providing a total of 619 student units.

Our approved Drainage Design was developed in line with Part H of the Building Regulations. It allowed for the attenuation and discharge of surface water to a nearby Thames Water sewer via gravity at a maximum rate of 7 l/s for all storm events up to and including the 1-in-100 year plus 40% climate change allowance.

A key challenge was the external areas available for the provision of SuDS were limited and only small zones were available for attenuation tanks. The Drainage Strategy therefore provided for attenuation via blueroofs for most of the building. Civilistix coordinated closely with the blueroof specialists to ensure that the attenuation strategy was implemented correctly and fully coordinated with the below ground drainage works.

A further challenge was that 2no. existing Thames Water sewers were crossing the site. Civilistix secured technical approval for the diversion works via a S185 application with Thames Water.

The foul water strategy proposed discharge via gravity for all foul water at ground floor and above to an existing Thames Water sewer, in Watkin Road. It was further proposed that the foul water at basement level would be discharged via a pumping station.

Civilistix worked in close collaboration with the wider design team to deliver a fully coordinated drainage solution for the client.

enhanced_road_safety_header

Vehicle Restraint Systems (VRS), commonly known as guardrails or crash barriers, are physical barriers installed along roadsides or medians to prevent vehicles from leaving the roadway or crossing over into opposing lanes. These systems are designed to redirect errant vehicles safely back onto the roadway, absorb impact energy, and minimize the likelihood of vehicles overturning or colliding with roadside hazards such as trees, utility poles, or steep slopes.

VRS come in various forms, including steel guardrails, wire rope barriers, concrete barriers, and crash cushions, each tailored to specific road geometries, traffic volumes, impact forces and site conditions.

They are strategically placed in areas prone to run-off-road accidents such as along sharp curves, bridges, medians, and other high-risk locations identified through comprehensive risk assessments.

The Road Restraint Risk Assessment Process (RRRAP) is an integral part of the design process which assists the Designer in determining at each specific site the need for VRS and its performance requirements.

It involves a multidisciplinary approach that encompasses engineering principles, risk analysis, and statistical modelling to assess the potential hazards posed by road infrastructure and determine suitable mitigation measures. The main document that provides guidance on the use of VRS and the RRRAP in United Kingdom is DMRB CD 377 – Requirements for road restraint systems. The RRRAP is normally applied in Motorways, All Purpose Roads and Other Classified Roads having a speed limit of 50 mph or greater and Average Annual Daily Traffic (AADT) of 5,000 or greater,

The RRRAP typically consists of the following key steps:

  1. Identification of Hazard Locations: Through data collection, site inspections, and accident analysis, hazard locations are identified where the likelihood of vehicle departure from the roadway or collision with roadside obstacles is high.
  2. Risk Analysis: Using established criteria and risk assessment tools, the identified hazards are analysed to quantify the level of risk posed to road users. Factors such as traffic volume, vehicle speed, road alignment, roadside features, and accident history are considered in this process.
  3. Selection of VRS: Based on the risk assessment results, appropriate Vehicle Restraint Systems are selected or designed to mitigate the identified hazards effectively. Factors such as containment capability, deflection characteristics, installation constraints, and cost-effectiveness are taken into account during the selection process.

Some advantages of the implementation of Vehicle Restraint Systems are:

  • Enhanced Safety:VRS significantly reduce the risk of serious accidents by containing errant vehicles and minimizing the severity of collisions.
  • Cost-Effectiveness:Properly implemented VRS can reduce the overall costs associated with road traffic accidents, including medical expenses and property damage.
  • Versatility:Various types of VRS can be tailored to specific roadway configurations and traffic conditions, offering versatility in design and application.

On the other hand, Vehicle Restraint Systems present challenges such as:

  • Maintenance Requirements:Ensuring the continued effectiveness of VRS requires regular inspection, maintenance, and repair, which can pose logistical and financial challenges.
  • Environmental Impact:The installation of VRS, particularly concrete barriers, can have environmental implications, including habitat disruption and visual intrusion.
  • Design Limitations:While VRS are effective in many scenarios, they may not provide adequate protection in all situations, such as collisions involving large vehicles or extreme impact angles.

Vehicle Restraint Systems and the Road Restraint Risk Assessment Process play indispensable roles in safeguarding road users and minimizing the impact of accidents. By understanding the principles behind these systems and implementing them effectively, transportation authorities can significantly enhance road safety and reduce the incidence of injuries and fatalities on our roadways. Continued research, innovation, and investment in these technologies are vital to meeting the evolving challenges of modern transportation infrastructure.

 

Civilistix Services Offered

Planning services: Planning Services Cambridge | Civilistix

Highway services: Highway Engineering Cambridge | Civilistix

Drainage engineering: Drainage Engineering Cambridge | Civilistix

Surveying services: Surveying Services | Civilistix

News & Views

Latest Updates

How Topographical Surveys Inform Drainage Design

November 12, 2026

How Topographical Surveys Inform Drainage Design

Topographical surveys help identify overland flow routes and low points where water may collect. Accurate survey information supports informed drainage design, flood risk assessment and site layout decisions from the outset.

Manhole Backdrops: The Pros and Cons

November 6, 2026

Manhole Backdrops: The Pros and Cons

Manhole backdrops can offer excavation savings and design flexibility, but introduce hydraulic and maintenance challenges. Their use requires careful consideration of site constraints, adoption requirements and long-term drainage system performance.

Why Drainage Easements Matter to Site Layout and Detailed Design

October 29, 2026

Why Drainage Easements Matter to Site Layout and Detailed Design

Drainage easements can influence building positions, drainage strategies and development costs. Identifying these constraints early helps project teams coordinate site layouts, maintain sewer access and avoid unnecessary redesign or diversions.