Linkedin

Newsletter Q3, 2024

November 7, 2024

As we approach the end of a busy and rewarding year we reflect on the exciting and diverse range of projects that our team have tackled this year. From large scale developments to assisting clients when they embark on that much anticipated extension/renovation.

We are thrilled to share that Francisco has been promoted to Senior Engineer – a well deserved recognition of his hard work and dedication – well done Fran!!

On a personal note, Dan, our director, has welcomed a new member to his family, a gorgeous baby boy.  We can’t wait to see if he will follow in his dad’s footsteps and become a skilled civil engineer one day.  Congrats to Dan and his family on this wonderful new chapter!

Our engineers have enjoyed sharing their knowledge and expertise through insightful articles on LinkedIn and our website.  We are grateful for your positive feedback and engagement, which has contributed to a nearly 40% increase in our LinkedIn followers. It is rewarding to see that our content resonates with you, and we value your positive feedback.

Time truly flies when you are having fun and this year is no exception.  Christmas is around the corner!  Hopefully the remainder of the year will be as exciting as the rest of the year and we look forward to the last few challenges and opportunities before we say goodbye to 2024.

Pumping stations are essential drainage infrastructure components, ensuring wastewater and stormwater are efficiently transported from lower to higher elevations where gravity flow is not possible. This article answers the questions:

  • What are the differences between adoptable and private pump stations?
  • What are the different types of pump stations?
  • What are the key design parameters for the design of pump station?

Adoptable vs. Private Pump Stations

Adoptable Pump Stations: Owned and maintained by sewerage undertakers, adoptable pump stations adhere strictly to industry regulations, predominantly Sewerage Sector Guidance (SSG). These stations must obtain approval (typically via a S104 application) from the relevant sewerage undertaker before construction can commence, ensuring compliance with rigorous design and construction standards.

Private Pump Stations: Owned and managed by private entities such as developers, private management companies or homeowners, private pump stations must predominantly meet Building Regulations Part H design requirement. The responsibility for operation, maintenance, and troubleshooting rests with the private owner, potentially leading to higher long-term costs and management complexities.

Key Parameters for Pump Station Design

Two critical parameters govern the design of pump stations:

Peak Pump Rate: This is the maximum flow rate a pump station can handle, crucial for meeting peak demand periods. Calculated by estimating average daily flow based on population and development type, this value is then multiplied by a peak factor (typically between 2 to 6) to accommodate daily usage fluctuations. Guidance from British Water’s Flows and Loads document offers estimates for daily flows per person across various development types.

Emergency Storage: This parameter refers to the volume available to contain inflows during pump station failures or maintenance periods. Calculated by multiplying the expected duration of non-operation (typically 24 hours as per Building Regulations Part H) by the inflow rate over that period, it ensures system reliability during emergencies. However, Sewerage Undertakers and local regulations may apply different approaches to determine this volume.

Types of Pump Stations

Private Pump Stations: Offered in a wide range of products tailored to specific applications and capacities, package pump stations stand out for their pre-assembled design, which simplifies installation and reduces on-site construction time and costs. Their compact footprint makes them suitable for confined spaces, while factory testing guarantees reliability and performance. Integrated control systems further enhance operational efficiency and monitoring capabilities.

Adoptable Pump Stations: Defined by the Sewerage Sector Guidance Appendix C, these stations are categorized into several types based on their capacity and application:

  • Type 1: Designed for small-scale usage with a peak flow rate of ≤ 0.25 litres per second, typically serving five dwellings or fewer.
  • Type 2: Handles moderate flow rates (> 0.25 to < 1 litre per second), accommodating between six to twenty dwellings.
  • Type 3: Supports higher flow rates (≥ 1 litre per second) for larger residential areas, with pump capacities up to 30 kW.
  • Type 4: Includes stations requiring pumps exceeding 30 kW, falling outside the scope of standard adoption guidelines, necessitating consultation with the relevant water company.

SSG Appendix C also specifies minimum distances from habitable buildings to pump station wet wells, which are crucial considerations influencing drainage strategy in terms of available space.

At Civilistix we know that pump stations are frequently used in drainage designs and as such it is important to understand the key parameters and different types of pump stations on offer.

Blue roofs are a sustainable drainage element designed to provide attenuation by temporarily storing rainwater and releasing it slowly. Their design includes features like drainage layers, flow control devices, and storage systems. With the increasing demand for Sustainable Drainage Systems (SuDS) in all types of projects, blue roofs are becoming more common, whether combined with green roofs or as an alternative to below-ground tanks.

When a blue roof is included in the design, input from various consultants is required early in the process:

  • Structural Engineers need to review the load-bearing capacity of the structure to determine the maximum water depth the roof can hold. This is particularly relevant when retrofitting blue roofs on existing buildings, where opportunities to upgrade the roof structure are limited. Additionally, in developments with buildings at different roof levels, the additional load of the blue roof might have cost implications for the overall structural design, depending on the level of installation.
  • Architects must work closely with blue roof specialists to coordinate the design of different insulation and waterproofing elements. When considering various values for maximum water height, the design must be reviewed carefully to determine if a thicker roof will cause internal space loss. If the roof design includes different uses and heights, the architect will also need to review the above-ground drainage strategy, determining where it is possible to install blue roofs, where water is collected, and the possibility of redirecting runoff from impermeable areas to the blue roof.
  • MEP (Mechanical, Electrical, and Plumbing) or Public Health Engineers are responsible for the above-ground drainage design inside the building. Their design will determine how rainwater is conveyed from the roof to the below-ground pipes. While architects provide the location of drain points at roof levels, MEP engineers need to coordinate the number and location of internal downpipes.
  • Civil Engineers are responsible for the below-ground drainage and the implementation of the drainage strategy. They will advise on how much water needs to be attenuated within the blue roof to comply with the strategy and coordinate their hydraulic design with the blue roof flow rates.
  • Blue Roof Specialists determine the final requirements for the correct performance. Their design includes hydraulic calculations that complement the civil engineer’s design.

Incorporating blue roofs into building projects offers a sustainable solution for managing rainwater, promoting better urban water management, and contributing to environmental sustainability. Successful implementation requires early and continuous collaboration among structural engineers, architects, MEP engineers, and civil engineers. By working together, these professionals can ensure that blue roofs are effectively integrated into the overall design, providing both functional and environmental benefits.

Civilistix Consulting Engineers were appointed to prepare a utility assessment to support a planning application for a proposed mixed-use development consisting of a 11-storey building (basement included).

It was proposed that the ground floor would be used for commercial use, consisting of 196m² of internal floor area, and floors above would be for residential use with 33 residential flat units and associated proposed external infrastructure.

The purpose of our utility assessment was to review the presence of all underground utilities operated by local statutory undertakers within the vicinity of the site to determine the effect, if any, the proposed development may have. This included:

  • Understanding the extents of existing utilities within the vicinity of the site.
  • Understanding the likelihood that the existing utility services could meet the utility demands of the proposed development.
  • Understanding whether the existing utilities would need to be built over or diverted as part of the development proposals.
  • Understanding any future utility considerations necessary to support development proposals

As part of the utility statement report, we were tasked with:

  • Obtain underground asset plans from all local utility providers operating within the area to confirm the extent of their underground utility assets within the vicinity of the development.
  • Prepare a combined utility plan showing the proximity of the development to all mainline services. This would give an idea as to connection feasibility and whether diversion of any existing services might be required as a consequence of the development proposals.
  • Prepare demand calculations for each utility in turn and apply for budget connection applications and capacity assessments on all proposed major services i.e. surface water, foul water, potable clean water, electricity & gas.

One of the key considerations in drainage system design is ensuring that the pipelines remain free of blockages, which can lead to costly maintenance and environmental hazards. The concept of self-cleansing velocity plays a critical role in achieving this goal.

Self-cleansing velocity refers to the minimum flow velocity required within a drainage pipe to prevent the accumulation of sediment and debris. When water flows through a drainage system at or above this velocity, it can effectively transport solids, preventing them from settling and leading to potential blockages. This concept is particularly vital in areas prone to high levels of sedimentation or where the drainage network is extensive and complex.

Importance in Drainage Design

Ensuring that the drainage system maintains self-cleansing velocity is essential for several reasons:

  1. Minimizing Maintenance Costs: Regular blockages in drainage systems necessitate frequent maintenance, which can be both time-consuming and expensive. Designing systems to achieve self-cleansing velocities reduces the likelihood of blockages, thereby lowering maintenance costs.
  2. Environmental Protection: Blockages can lead to overflows, which might result in untreated wastewater contaminating the environment. By maintaining appropriate flow velocities, the risk of such environmental hazards is significantly reduced.
  3. Operational Efficiency: A well-maintained drainage system that operates at self-cleansing velocity ensures that the infrastructure performs optimally over its lifespan, reducing the need for costly repairs or replacements.

Factors Influencing Self-Cleansing Velocity

Several factors influence the self-cleansing velocity within a drainage system, including:

  • Pipe Material: The roughness of the pipe’s internal surface can impact the velocity required to prevent sedimentation. Smoother materials like plastic require lower velocities compared to rougher materials like concrete.
  • Pipe Diameter: Larger diameter pipes may require higher velocities to achieve self-cleansing due to the increased surface area where sediment can settle.
  • Slope of the Pipe: Steeper slopes naturally encourage faster flow velocities, reducing the need for additional measures to maintain self-cleansing conditions.
  • Type of Sediment: The size and weight of the sediment being transported affect the velocity needed. Heavier particles require higher velocities to remain in suspension.

The primary guideline for determining self-cleansing velocities in private pipe networks in England is BS EN 16933-2 (2017) – Drain and Sewer Systems Outside Buildings – Hydraulic Design.

For adoptable sewerage systems, the Sewerage Sector Guidance (SSG) Appendix C specifies that the minimum self-cleansing velocity should generally be 0.75 m/s for foul sewers and 1.0 m/s for surface water sewers. These recommended velocities are intended to ensure that the drainage system effectively prevents sediment deposition under normal operating conditions.

The relationship between velocity (V), flow rate (Q), and cross-sectional area (A) of a drainage pipe is fundamental in understanding how to achieve and maintain self-cleansing velocity. This relationship is described by the equation:

Where:

  • V is the velocity of flow (m/s),
  • Q is the flow rate (m³/s),
  • A is the cross-sectional area of the pipe (m²).

This equation demonstrates that the velocity of flow within a pipe is directly proportional to the flow rate and inversely proportional to the cross-sectional area of the pipe.

Conclusion

Self-cleansing velocity is a fundamental concept in drainage design that ensures the long-term efficiency and reliability of drainage systems in the UK. By carefully considering factors such as pipe material, diameter, slope, and sediment type, and understanding the relationship between velocity, flow rate, and area, engineers can design systems that minimize blockages, reduce maintenance costs, and protect the environment. As the demand for more sustainable urban drainage solutions grows, maintaining self-cleansing velocity will remain a critical consideration in the effective management of water resources.

Soakaways are used to infiltrate surface water into the ground.

Typically, soakaways must be able to attenuate surface water with no flooding during the critical 1 in 100 years plus 40% climate change event and half drain within 24 hours to meet current best practice design guidance.

Soil consistency varies considerably across the UK. Therefore, the infiltration rate of the ground needs to be established at the site of the proposed soakaway to establish a suitable design infiltration rate.

The infiltration rate is influenced by soil type, soil structure and moisture content among other factors

In order to establish a suitable design infiltration rate, an infiltration test to BRE 365 should be conducted. Typical requirements of BRE 365 are as follows:

Infiltration Guidelines:

  • A trial pit should ideally be excavated at the location of the proposed soakaway. This needs to be at least 5m away from the existing or proposed building footprint.
  • A trial pit must be rectangular in shape and excavated in accordance with the following size dimensions – size: 1-3m length; 0.3-0.1m width and 1-2m depth.
  • Detailed logging of ground strata should be undertaken, including information such as topsoil, made ground, clay depth and ground water levels.
  • Photographic evidence should be documented at separate times during the procedure.

Infiltration Test Procedure:

Once the excavation pit has been dug, it should be quickly filled with water to 75% of its depth.

A record is then kept of the time taken for the water level to reach 25% of the pit depth.

This procedure should be repeated 3 times for each BRE 365 trial pit. The depth of the water should generally be recorded every 10 minutes or every 100mm that the water level drops.

Calculating Infiltration Rate:

As of BRE 365 infiltration methodology, soil infiltration rate can be determined as follows:

Where:

Vp75-25 : effective storage volume of water in the soakage trial pit between 75% and 25% effective storage depth.

∂s50 : internal surface area of the soakage trial pit up to 50% effective storage depth, including the base area.

tp75-25   the time for the water level to fall from 75% to 25% effective storage depth.

Design of Soakaway

As the infiltration test is repeated 3 times, 3 results for each trial pit are calculated.

The worst (smallest value) infiltration rate is used in the design of the proposed soakaway.

Generally, an infiltration rate of >1 x 10-6 m/s, is considered suitable for infiltration discharge to the ground, allowing for half drain down time within 24 hours.

An overview of general infiltration rates for each type of strata is provided below:

Typical values for the Infiltration Rate of Soils (Courtesy of CIRIA 753; The SUDS Manual)

Summary

An infiltration test to BRE 365 is pivotal in the design of effective soakaways.

Accurate site-specific testing and careful design ensure that soakaways effectively manage surface water, comply with regulations and mitigate the risk of flooding.

 

Civilistix Services Offered

Planning services: Planning Services Cambridge | Civilistix

Highway services: Highway Engineering Cambridge | Civilistix

Drainage engineering: Drainage Engineering Cambridge | Civilistix

Surveying services: Surveying Services | Civilistix

 

News & Views

Latest Updates

How Topographical Surveys Inform Drainage Design

November 12, 2026

How Topographical Surveys Inform Drainage Design

Topographical surveys help identify overland flow routes and low points where water may collect. Accurate survey information supports informed drainage design, flood risk assessment and site layout decisions from the outset.

Manhole Backdrops: The Pros and Cons

November 6, 2026

Manhole Backdrops: The Pros and Cons

Manhole backdrops can offer excavation savings and design flexibility, but introduce hydraulic and maintenance challenges. Their use requires careful consideration of site constraints, adoption requirements and long-term drainage system performance.

Why Drainage Easements Matter to Site Layout and Detailed Design

October 29, 2026

Why Drainage Easements Matter to Site Layout and Detailed Design

Drainage easements can influence building positions, drainage strategies and development costs. Identifying these constraints early helps project teams coordinate site layouts, maintain sewer access and avoid unnecessary redesign or diversions.