A Busy and Productive Summer!

It has been a busy and productive summer for Civilistix, with a strong pipeline of newly secured projects alongside our ongoing work. These new commissions cover a broad range of services, including surface and foul water drainage strategies, flood risk assessments, external hardstanding design and adoptable highway design.

As our workload continues to grow, so does our team. This quarter, we were delighted to welcome Josh Brabbins as our newest Senior Civil Engineer. Josh brings valuable experience and expertise to Civilistix and will help us continue providing the high-quality, right-first-time designs our clients have come to expect.

We are grateful for the continued support of our clients and look forward to sharing a selection of our projects and technical insights in this latest edition.

A question we often get asked is: “Can I retrofit SuDS into my development or around my property?”

The short answer is YES!

Sustainable Drainage Systems (SuDS) can be successfully integrated into existing developments, bringing a range of practical and environmental benefits. The approach and cost will depend on the site and budget, but in most cases, something can be done to make a positive difference.

While new developments are now required to include SuDS as part of the planning process, there is less formal guidance for existing properties. However, as drainage design standards and modelling have advanced significantly in recent years, retrofitting SuDS has become an effective way to improve flood resilience and water quality.

Benefits of retrofitting SuDS features include:

  • Reduced flood risk – by slowing and storing surface water runoff.
  • Improved water quality – through natural filtration of pollutants before discharge.
  • Enhanced biodiversity and amenity – incorporating planting and green spaces.
  • Reduced water use and maintenance – encouraging infiltration and water reuse.
  • Improved resilience – protecting properties and infrastructure from flooding.

Ways to Retrofit SuDS

Permeable Paving:

Permeable paving allows rainwater to soak through the surface instead of running off it. Depending on ground conditions, the surface water can either infiltrate into the soil below or be collected via perforated pipes and directed into the existing drainage system. There are numerous options available, from permeable block paving to porous asphalt, thereby accommodating most driveways, car parks and pathways.

Rain Gardens and Tree Pits:

Rain gardens and tree pits offer an effective way to manage surface water while enhancing green space. They are particularly well suited to locations where water naturally gathers, such as beside parking areas or along building edges. Surface water can be directed into these features by diverting downpipes or installing drop kerbs. In addition to managing runoff, rain gardens and tree pits support biodiversity and contribute to the visual and environmental quality of urban spaces.

Water Butts:

One of the simplest and most cost-effective option is fitting water butts to downpipes to collect roof water. The stored water can be reused for gardening or cleaning, with any overflow directed back into the existing drainage system. This small change can help reduce demand on the drainage network and can help reduce water bills.

Green Roofs:

For properties with flat or gently sloping roofs, a green roof can be a great retrofit option. Green roofs absorb rainfall, slow down runoff, and add insulation while improving biodiversity. Some lightweight systems have been developed that can be fitted to existing roof structures. However, it is essential that the roof structure is professionally checked to confirm that it can accommodate the additional load of a green roof.

Infiltration Trenches:

Infiltration trenches are another simple SuDS solution. They are gravel-filled trenches that collect and gradually disperse surface water into the surrounding ground. This is a common feature that is used along driveways, garden edges and open spaces. Infiltration trenches are low-maintenance and can make a noticeable difference without costly or complex construction works.

 In Summary

Retrofitting SuDS is a great way to manage surface water and does not have to be expensive or complicated. Small changes can have a noticeable effect on how a site deals with surface water runoff.

Every property is different, so it is advisable to consult a civil engineer or SuDS specialist to explore practical solutions that provide the greatest benefit.

Civilistix Consulting Engineers were appointed to prepare a Flood Risk Assessment (FRA) and Drainage Strategy to support a planning application to repurpose a disused water treatment plant at Old Ford Island on the western edge of the Queen Elizabeth Olympic Park. The purpose of this project was to provide a new home for the teams responsible for the security, management, and landscape maintenance of the park.

The site is located within Flood Zone 3 and a detailed review of the flood extent and levels was required to determine how to safely implement the development proposals, and to identify opportunities for the use of Sustainable Drainage (SuDS) techniques. Upon consultation with the Environment Agency, Civilistix identified the areas which were at high risk of flooding. A site-wide strategy was prepared to ensure the new buildings would not be at risk of flooding and that surface water discharge would not be displaced resulting in issues elsewhere.

Civilistix followed the surface water run-off hierarchy as per Part H of the Building Regulations Act, to design the surface water Drainage Strategy. The Drainage Strategy included 2 different options for surface water discharge due to the limited opportunities to conduct site investigations:

  • Infiltration disposal was the primary consideration given the ballast bedrock identified. However, based on a review of the recorded drawings and borehole logs, it was noted that there might be a risk of contamination of the groundwater and consequently an alternative disposal method should be reviewed.
  • A pumped controlled discharge was considered within the strategy should infiltration not be feasible once the final ground investigation works are completed.

It was proposed that the full external hardstanding area would utilise tanked permeable paving construction, which would accommodate voided Type 3 sub-base material, and an attenuation basin for the discharge of the roofs runoff. This would allow for the treatment of runoff and sufficient attenuation storage volume so that the control water of 2.0 l/s would be ensured. Further to the above measures, it was proposed that green and blue roofs be incorporated in the roof areas, thus providing interception storage, slowing down runoff and providing treatment.

All Foul Water would be gravity fed to an existing Thames Water Foul Water Sewer.

Civilistix worked in close collaboration with other design teams to deliver a fully coordinated proposed external works and drainage design solution for the client, which was granted planning permission.

The adoption of a pumping station and its associated rising main by a water statutory undertaker under a Section 104 of the Water Industry Act 1991, is an option developers may pursue to secure the long-term serviceability and maintenance of the asset.  This approach benefits future residents of the development by avoiding the complexities and liabilities associated with private maintenance schemes.

The design of an adoptable pumping station should be in accordance with ‘Sewerage Sector Guidance – Approved Documents’ and the ‘Local Practices’ published by each statutory water undertaker.

Before a S104 submission is formally made, there are several considerations that developers and designers should consider to ensure that the proposals are adequate, and the technical approval process is streamlined:

Location of the pumping station and associated pipework

Determining the most suitable location for the pumping station is one of the first and most important steps in the design process.

Key considerations include:

  • Odour, noise and nuisance: The pumping station should be located an appropriate distance from any habitable buildings to minimise the risk – typically 5 – 15 meters (depending on the size and use of the pumping station).
  • Accessibility: The enclosure should be easily accessible from a public road, and typically not further than 60m from the public highway.
  • Flood risk: The site should not be at risk of flooding from any source.
  • Vehicle access: A detailed swept path and visibility analysis should be carried out to ensure the relevant maintenance vehicle can safely access and navigate the site.
  • New highway access: If a new access road is to be provided, the works will be subject to S278 approval from the relevant Highways Authority.
  • Rising main location: The rising main should also be offered for adoption, and therefore consideration should be made to its location early on in the design process.

Hydraulic Design

Flow Calculations:

The performance of the pumping station and rising main is determined by the daily flow volume.

  • Residential developments: The standard volume is 4000 litres per dwelling per day.
  • Other domestic flows: These should be calculated in accordance with BS EN 12056-2 System II, which is based on the flow discharge rates from individual foul appliances.
  • For large developments: Large developments where single units have minimal influence on overall flow, calculations should be based on a measured rate of flow per head. Code of Practice: Flows and Loads – 4, provides for the typical daily volume for different types of

developments. Where detailed information is not available, a design flow of 0.6 litres per second, per hectare of developable land, may be adopted.

  • Trade effluent flows (wastewater from industrial processes): Flows should be based on metered discharge data from similar premises or assumed as:
    1. 0.5 L/s/ha for normal industrial use,
    2. 1.0 L/s/ha for wet industry, or
    3. 0.7 L/s/ha where the proportion of wet industry is unknown.

Emergency Storage:

Emergency storage should be included to allow for pump failure or maintenance.

  • Adoptable standards require the following:
    1. For developments of less than 500 dwellings, the storage should provide for a minimum of 160 litres per dwelling.
    2. For 500 dwellings or more, the sewerage company should be consulted to determine the storage requirements.
  • For commercial or industrial developments: Storage should provide for a minimum of one hour’s peak design flow rate.

Rising Main:

  • The rising main should be designed to ensure self-cleansing velocities, and to avoid sediment settlement in low points, or air locking and pressure build-up at high points. This is achieved through the use of washout chambers at low points and air valves at high points.
  • For rising mains longer than 500m, the following additional risks should be reviewed:
    1. Retention time and the associated septicity risks
    2. The impacts of hydraulic surge
    3. The effects of cyclic loading on the fatigue life of the materials.

Structural and MEP design

  • The final hydraulic and electrical design of the pumping equipment should be developed by a qualified Mechanical and Electrical engineer.
  • The design of each of the components will require a formal design by a structural engineer, as well as a detailed Ground Investigation to inform the design.
  • Parts of a sewage pumping station can be hazardous zones. It should be discussed with the sewerage company at an early stage whether a DSEAR (Dangerous Substances and Explosive Atmospheres Regulations) assessment should be undertaken by a relevant specialist and a report compiled.

 

Civilistix Services Offered

We are a Civil Engineering Design Consultancy – a One Stop Shop for:

Planning services: Planning Services Cambridge | Civilistix

Highway services: Highway Engineering Cambridge | Civilistix

Drainage engineering: Drainage Engineering Cambridge | Civilistix

Surveying services: Surveying Services | Civilistix

We would love to help you with your next project! Contact us | Civilistix

News & Views

Latest Updates

How Topographical Surveys Inform Drainage Design

November 12, 2026

How Topographical Surveys Inform Drainage Design

Topographical surveys help identify overland flow routes and low points where water may collect. Accurate survey information supports informed drainage design, flood risk assessment and site layout decisions from the outset.

Manhole Backdrops: The Pros and Cons

November 6, 2026

Manhole Backdrops: The Pros and Cons

Manhole backdrops can offer excavation savings and design flexibility, but introduce hydraulic and maintenance challenges. Their use requires careful consideration of site constraints, adoption requirements and long-term drainage system performance.

Why Drainage Easements Matter to Site Layout and Detailed Design

October 29, 2026

Why Drainage Easements Matter to Site Layout and Detailed Design

Drainage easements can influence building positions, drainage strategies and development costs. Identifying these constraints early helps project teams coordinate site layouts, maintain sewer access and avoid unnecessary redesign or diversions.