December 11, 2025
The days are a little shorter and the Christmas season has arrived along with carols and lights and the wonderful anticipation of spending time with family and friends.
As we close out 2025, we take time to reflect on what this year has meant to us as a business and a team. It has been a productive and rewarding year, marked by new clients and several exciting new projects we are proud to be involved in. We also appreciate the continued support and collaboration with many of our valued clients and partners who have been with us throughout the years.
We would like to extend a big THANK YOU for your support in 2025. We look forward to building on this year’s momentum and working together again in 2026!

In the UK, the design of highways is a critical component of our infrastructure, influencing safety, efficiency, and sustainability. Among the key elements of highway design are vertical and horizontal alignments—two facets that shape the functionality and user experience of our road networks.
Horizontal Alignment:
Horizontal alignment refers to the layout of a road in plain view, considering curves and straight sections. This aspect of design ensures that vehicles can navigate turns safely and comfortably, without unnecessary strain. Key considerations in horizontal alignment include:

Source: Nottinghamshire County Council, Stopping Sight Distance (SSD)
Vertical Alignment
Vertical alignment focuses on the elevation of the road along its length, considering gradients and vertical curves. A well-designed vertical alignment is essential for visibility, drainage, and energy efficiency. Some critical aspects include:
K = L / A
Where:
3. Visibility: Vertical alignment must ensure that sight distances are adequate for safe stopping and overtaking manoeuvres, especially on crest curves. Proper visibility is a critical safety consideration in highway design.
4. Super-Elevation: Banking the road surface on curves helps counteract centrifugal forces, ensuring vehicles maintain grip and stability.
All the parameters mentioned above—including curve radius, super-elevation, SSD, gradients, and vertical curve design (K value)—can be derived from DMRB CD 109. This document provides the necessary guidelines to align design choices with safety and operational standards based on the road’s design speed. However, it is important to note that many local highway authorities have their own specific requirements for these parameters. Therefore, it is essential to consult local standards and guidelines to ensure compliance with regional requirements.

DMRB CD109 – Table 2.10 Design speed related parameters
At Civilistix, our experienced civil engineers will gladly assist with your detailed highway designs needs. We focus on safety, efficiency, and sustainability in all our designs.

In urban planning and construction, the terms greenfield and brownfield sites are often used to describe different types of land available for development. While both refer to land that can be built on, they have fundamental differences that impact drainage opportunities and risks. Here is a breakdown:
Greenfield Site
Definition: A greenfield site refers to undeveloped land, typically in a rural or semi-rural areas that has never been built on or used for industrial, commercial, or residential development.
These sites are often agricultural land, countryside or natural spaces that have not previously been developed such as farmlands, forests and open fields areas.
Drainage Opportunities:
Drainage Risks:
Planning approval: Developing greenfield sites in the UK often faces opposition due to environmental concerns and policies aimed at protecting the countryside and preventing urban sprawl. In line with the National Planning Policy Framework (NPPF), greenfield developments must undergo thorough environmental assessments, and approval can be difficult to obtain without proper justification.
Brownfield Site
Definition: A brownfield site refers to previously developed land, often in urban or industrial areas. This type of land is typically being repurposed or redeveloped.
These sites were previously used for industrial, commercial, or residential uses, such as old factories, warehouses, abandoned buildings or old residential properties that are now being replaced by new developments.
Drainage Opportunities:
Drainage Risks:
Planning Approval: In the UK, redeveloping brownfield sites is actively encouraged by the government as part of sustainable development strategies. The NPPF prioritises brownfield regeneration to reduce the environmental impact of new developments and preserve greenfield land for future generations.
Conclusion
Both greenfield and brownfield sites offer unique opportunities for development but come with their own set of challenges with regards to drainage design. Greenfield sites often offer a more straightforward development process but raise significant environmental concerns. In contrast, brownfield sites can be more complex due to potential contamination, utilities and limited space issues but are aligned with sustainable urban regeneration goals.
Ultimately, the decision to develop on a greenfield or brownfield site depends on project objectives, environmental impact, and cost considerations.

Services offered
Civilistix was responsible for preparing the detailed designs for drainage, external hardstanding, and highway works for the proposed development encompassing a 27-storey student accommodation building, including two basement floors and associated external hardstanding areas.
The approved Drainage Strategy initially relied on gravity discharge to Deptford Creek at the Mean High Water Spring level. However, during the detailed design stage, it became evident that surface water discharge could be restricted when water levels in Deptford Creek exceeded the outfall level. To mitigate this, we proposed a pumped surface water discharge system to ensure reliable outflow. A Drainage Strategy Addendum was subsequently prepared and submitted to the Lead Local Flood Authority (LLFA) for approval.
Our Surface Water Drainage Strategy incorporated a geo-cellular storage tank and Type 3 permeable paving sub-base, allowing for the attenuation of surface water runoff before it was discharged at a controlled rate of 2.0 l/s via a package pumping station, into Deptford Creek.
For foul water drainage, the proposed system included a private package pumping station in the basement, which discharged into the combined public sewer along Norman Road. We also secured Thames Water approval for the diversion of an existing foul water sewer via a Section 185 agreement, together with Section 106 approval for the sewer connection.

Due to the building being greater than 7 storeys, all our civil design work was subject to gateway approval under the Building Safety Act, to which we worked with the team to secure.
Our scope included the adoptable highway design (S278) and site frontage improvements along Norman Road. The works encompassed enhanced vehicular access, reconstruction of the footway, and the provision of new Blue Badge parking and loading bays to improve accessibility and transport infrastructure.
Through our comprehensive design approach, we effectively addressed complex drainage challenges while ensuring full regulatory compliance and coordination with other design teams.


The National Standards for Sustainable Drainage Systems (SuDS), published in July 2025, are a big step for drainage design in England. For a long time, engineers, developers, and councils have been working with mixed guidance and sometimes different expectations. Now, at least, we have a clear national set of rules that show what “good SuDS” should look like.
But what does this mean when we are actually designing drainage?
Key changes shaping design
Are the new standards mandatory?
The National Standards for SuDS are a significant step forward, but they are not statutory as yet. Schedule 3 of the Flood and Water Management Act 2010 still has not been enacted.
This leaves some room for interpretation. However, the National Planning Policy Framework (NPPF) already requires LPAs to promote sustainable drainage, and many authorities are likely to treat these new standards as their reference point.
For developers and planning consultants, this means that compliance is becoming essential. Even if not enforced by statute, failure to align with the standards could lead to planning delays, costly revisions, or refusals.
What this means in practice for design
From a civil engineering design perspective, the new standards will influence both how we design and how we communicate our designs.
A step change for drainage engineers
The new SuDS standards will not dramatically change the principles of good design – many engineers have already been working towards these outcomes. What they do is raise expectations and provide consistency.
Yes, it means more upfront design, more coordination and more detailed reports, but it also gives us a chance to design drainage that is not only compliant, but resilient and genuinely useful to the places we build.
For our drainage engineers at Civilistix, we view this as both a challenge and an opportunity – a chance to show the real value of Good Design.

Can I have rainwater downpipes that discharge into a raingarden that then infiltrate into the ground right next to a building?
This question often arises when developers are required to implement SuDS (Sustainable Drainage Systems) that provide multiple benefits and infiltration is a viable option.
Raingardens are among the simplest SuDS features to implement and maintain. They are typically designed to attenuate surface water at ground level, so it would seem logical to have them located in close proximity to a building to collect roof runoff directly from downpipes.
However, Building Regulations Part H states that any infiltration device, such as a soakaway, should be at least 5 metres from a building. While raingardens are not explicitly mentioned in the regulations, they function in a similar way when they allow infiltration. Therefore, the same 5-metre rule should be applied.
Connecting a significant roof area directly to a raingarden which discharges via infiltration could potentially create a new groundwater pathway next to a building and have a detrimental impact on the structure’s foundations. In the event of surcharge or system failure, locating these features too close to a structure could increase the risk of flooding.
Practical solutions include:

News & Views

November 6, 2026
Manhole backdrops can offer excavation savings and design flexibility, but introduce hydraulic and maintenance challenges. Their use requires careful consideration of site constraints, adoption requirements and long-term drainage system performance.

October 29, 2026
Drainage easements can influence building positions, drainage strategies and development costs. Identifying these constraints early helps project teams coordinate site layouts, maintain sewer access and avoid unnecessary redesign or diversions.

October 23, 2026
Safe pedestrian routes require careful coordination where they cross vehicle accesses. We explore how layout, visibility, vehicle speeds, accessibility and drainage help create safe pedestrian crossings.