July 8, 2026

Infiltration is often considered the preferred method of surface water disposal, but a successful infiltration test alone does not automatically mean infiltration is feasible. Groundwater levels, contamination risks, site topography and drainage performance all need to be considered before infiltration-based SuDS can be taken forward.
This article looks at some of the key factors that determine whether infiltration is likely to be a viable drainage solution.
One of the first considerations is whether the ground can infiltrate water at a sufficient rate.
This is typically assessed through BRE365 infiltration testing, where a trial pit is excavated, filled with water and monitored over time. The results are used to calculate an infiltration rate which can then inform the design of the drainage system. The resulting infiltration rate must be sufficient to allow the proposed feature to recover storage capacity between rainfall events, commonly assessed through half-drain time calculations.
As a rule of thumb, many authorities expect infiltration features to half-drain within approximately 24 hours for more frequent design events, while larger communal SuDS features may be afforded longer half drain down times in accordance with CIRIA C753 guidance.
Groundwater can have a significant impact on whether infiltration is feasible.
A common requirement is that a minimum clearance of 1.0 m should be maintained between the base of the infiltration structure and the maximum anticipated groundwater level. The CIRIA SuDS Manual also promotes greater separation where possible, with around 1.2m often considered desirable.
Where groundwater levels are too high, infiltration performance can be significantly reduced, and long-term operation may become unreliable.
For this reason, infiltration testing is often supported by trial pits, groundwater monitoring or geotechnical investigations.
Ground conditions must also be considered.
On brownfield sites, historical land uses may have resulted in contamination within the underlying soils or groundwater. In these circumstances, infiltration can create pathways for pollutants to migrate into groundwater and the wider environment.
Where contamination is suspected, additional investigation and testing may be required before infiltration can be considered suitable.
In some cases, infiltration may be discounted altogether, particularly where significant made ground or contamination is present.
Highly permeable sands and gravels on sloping sites can occasionally result in groundwater seepage or springs emerging further downslope. This can create stability concerns, wet ground conditions or impacts on adjacent land.
The wider geology and topography of a site should therefore be considered alongside infiltration testing results.
Summary
A common misconception is that a successful BRE365 test automatically means infiltration is feasible.
While BRE365 testing and infiltration rates form an important part of the assessment, approving authorities will typically consider a range of factors including half-drain performance, groundwater levels, contamination risks, geology and site topography before accepting infiltration as a suitable drainage solution.
Understanding these constraints early in the design process can help identify whether infiltration is likely to be viable and reduce the risk of redesign further on in a project.
Further Reading
Civilistix Services:
Drainage Engineering Cambridge | Civilistix
Surveying Services | Civilistix
News & Views

November 6, 2026
Manhole backdrops can offer excavation savings and design flexibility, but introduce hydraulic and maintenance challenges. Their use requires careful consideration of site constraints, adoption requirements and long-term drainage system performance.

October 29, 2026
Drainage easements can influence building positions, drainage strategies and development costs. Identifying these constraints early helps project teams coordinate site layouts, maintain sewer access and avoid unnecessary redesign or diversions.

October 23, 2026
Safe pedestrian routes require careful coordination where they cross vehicle accesses. We explore how layout, visibility, vehicle speeds, accessibility and drainage help create safe pedestrian crossings.