Linkedin
CASE STUDY

1-3 & 9 Watkin Road, Wembley

Detailed Drainage & External Hardstanding Design and Sewer Agreements

Service offered

  • Detailed Drainage & External Hardstanding Design
  • Sewer Agreements

The brief

Civilistix Consulting Engineers were appointed to prepare the Detailed Drainage & External Hardstanding Design, together with the sewer agreements for Thames Water S185 approval. These works supported the construction of 2no. tower blocks (27 and 18 storeys respectively), delivering a total of 619 student units.

What we did

Our approved Drainage Design was developed in line with Part H of the Building Regulations. It allowed for the attenuation and discharge of surface water to a nearby Thames Water sewer via gravity at a maximum rate of 7 l/s for all storm events up to and including the 1-in-100 year plus 40% climate change allowance.

A key challenge was the external areas available for the provision of SuDS were limited and only small zones were available for attenuation tanks. The Drainage Strategy therefore provided for attenuation via blueroofs for most of the building. Civilistix coordinated closely with the blueroof specialists to ensure that the attenuation strategy was implemented correctly and fully coordinated with the below ground drainage works.

A further challenge was that 2no. existing Thames Water foul and surface water sewers were crossing the site. Civilistix secured technical approval for the diversion works under a S185 application with Thames Water.

The foul water strategy proposed discharge via gravity for all foul water at ground floor and above to an existing Thames Water sewer, in Watkin Road. It was further proposed that the foul water at basement level would be discharged via a pumping station.

Civilistix worked in close collaboration with the wider design team to deliver a fully coordinated drainage solution for the client.

 

Civilistix Services:

Planning Services Cambridge | Civilistix

Drainage Engineering Cambridge | Civilistix

Sewer Connections & Discharge Consents | Civilistix