Detailed Surface & Foul Water Drainage Strategy
Civilistix Consulting Engineers were appointed to prepare a detailed surface and foul water drainage strategy, for the creation of 22no. residential dwellings, along with amenity space, access roads, car parking, and other external hardstanding area.
BRE 365 infiltration testing was undertaken and uncovered high ground water. Due to the presence of high ground water found on site, discharging surface water via soakaways was ruled out. As a result, a controlled connection was proposed to an existing ditch along Green Lane. The proposed runoff was discharged at 2.14l/s for all storm events, up to and including the critical 1 in 100-year storm event plus 40% climate change allowance.
SuDS in the form of lined permeable paving and geo-cellular storage tanks were proposed for treating and providing attenuation storage for surface water runoff for the proposed development.
Our engineers proposed all foul water flows from the development be discharged via gravity into an existing 150mm Thames Water (TW) foul water sewer within Green Lane.
Civilistix Services:
Planning Services Cambridge | Civilistix