Detailed Drainage Design and BRE365 Infiltration Testing
Civilistix Consulting Engineers were appointed to prepare a detailed surface and foul water drainage design, for the redevelopment of a brownfield site to accommodate a large residential dwelling, together with car parking and associated external hardstanding.
Civilistix undertook a BRE 365 infiltration test which confirmed suitable ground conditions for infiltration.
Our proposed SuDS Drainage design allowed for all permeable paving hardstanding extents to discharge runoff via infiltration, and the proposed roof hardstanding to discharge via a soakaway. All SuDS features were designed to accommodate the 1 in 100-year storm event plus 40% climate change allowance.
A significant challenge was the absence of a public foul sewer within the vicinity of the site. In addition, site constraints prevented treated foul water from discharging via a drainage field. To overcome this, we designed a foul drainage solution incorporating two cesspool tanks, sized to accommodate 50 days of foul water storage.
Drainage proposals were coordinated with tree root protection zones to minimise the impact from the proposed works on retained mature trees as well as other site constraints.
The result was a robust, sustainable drainage design that addressed challenging site constraints, supporting the successful redevelopment of the site.
Civilistix Services:
Planning Services Cambridge | Civilistix